Universal Intermittent Pilot Ignition Control S8610U3009
Universal Intermittent Pilot Ignition Control
Order #:L37-808
Mfg. #:
S8610U3009
Brand:
Honeywell Home
- Replaces over 400 Honeywell and competitive models
- Easy field replacement for most intermittent pilot modules LED flame strength indicator and a diagnostic LED that helps direct service efforts
Part Description:
- Ignition Control Module
- Type Universal, Intermittent Pilot
- Fuel Type Natural/Liquid Propane Gas
- Flame Sense Type Single or Dual Rod
- Ignition Source Internal High Voltage Spark Generator
- Ignition Sequence Continuous Retry
- Ignition Trial Time 15/90 Second
- Prepurge Time Configurable to 30 Second/No Pre-Purge
- Flame Failure Response Time 2 Second
- Valve Rating 1 Amp Pilot/2 Amp Main at 165 Deg F, 1 Amp Pilot/Main at 175 Deg F
- Power Rating 24 Volt AC at 60 Hertz
- Size 5-7/16 Inch Width x 2-5/8 Inch Depth x 3-15/16 Inch Height
- Temperature Rating -40 to 165 Deg F
- Application Warm Air Furnace, Heating Appliance
- Approval CSA
- Includes Damper Connection, Automatic Vent Damper Plug
UPC: 662766427370
Part Number: S8610U3009/U
Features / Benefits
- Universal Intermittent Pilot Ignition Module Replaces Multiple Field Installed Intermittent Pilot Modules
- Uses Existing Intermittent Pilot Burner
- Provides Ignition Sequencing, Flame Monitoring and Safety Shut-Off for Intermittent Pilot Warm Air Furnace and Heating Appliances
- Provides 100 Percent Pilot Gas Shut-Off If Pilot Fails to Light
- After 6 Minute Delay, Trial for Ignition is Repeated
- Ignition Trial/Delay Sequence is Repeated Until the Appliance Lights or Call for Heat is Removed
Specifications
MANUFACTURER | HONEYWELL RESIDENTIAL |
MANUFACTURER PART NUMBER | S8610U3009/U |
METROPAC INTERNAL PART NUMBER | 108934 |
ADDITIONAL INFORMATION | Includes Damper Connection, Automatic Vent Damper Plug |
MARKETING TEXT | Universal intermittent pilot ignition module replaces multiple field installed intermittent pilot modules supplied by Honeywell, Robertshaw, Johnson, and UTEC (HSC). Uses existing intermittent pilot burner. Includes cross reference, instructions, and accessories for easy replacement. |
PRODUCT NAME | Ignition Control Module |
UPC CODE | 662766427370 |