Technician Notes

  • Always disconnect line voltage before servicing the control transformer.

  • Mount transformer on a solid, vibration-free surface using all four mounting holes.

  • Wire primary leads to the 120 VAC supply line; observe polarity if color coded.

  • Connect secondary leads to the 24 VAC control circuit (thermostat/gas valve); secure with UL-rated connectors.

  • After wiring, energize and verify 24 VAC output under load with a multimeter.

  • Ensure transformer case is properly grounded to chassis.


Compatibility

Application Compatible Models / Series
Coleman Gas Furnaces 7600, 7700 series requiring 24 VAC control voltage
York & Goodman Furnaces Residential and light-commercial units needing a 40 VA transformer
Control Boards & Relays Any HVAC control circuit designed for 24 VAC at 40 VA load

Description

120V-PRI 24V-SEC 40VA TRANSFOR

120V-PRI 24V-SEC 40VA TRANSFORMER YORK GOODMAN Coleman 

Replaces 7650B350, 7660B3501 

Compatible Coleman/York/Goodman Models

The S1-2940A3541 120 V→24 V, 40 VA control transformer is used on the following model designations:

  • DGAA056BDTA

  • DGAA070BDTA

  • DGAA077BDTA

  • DGAA090BDTA

  • DGAA056BDTB

  • DGAA070BDTB

  • DGAA077BDTB

  • DGAA090BDTB

  • DGAH056BBSA

  • DGAH077BBSA

  • DGAH056BBSB

  • DGAH077BBSB

  • DGPH056ABTA

  • DGPH070ABTA

  • DGPH077ABTA

  • DGPH090ABTA