62-24140-04 Rheem OEM Replacement Control Direct Spark ICM292A

Rheem OEM Replacement Control


Direct Spark Ignition (DSI) Control Board

The ICM292A is a low-cost DSI gas ignition control that replaces the following Rheem model: 62-24140-04. The ICM292A has incorporated LED diagnostics to assist in troubleshooting.

Fault code information can be found in the application guide. Please refer to the application guide or furnace installation manual for future reference.

DETAILS:

  • Low cost form, fit and functional replacement for Rheem: 62-24140-04
  • Direct Spark Ignition (DSI) control
  • Microprocessor-based
  • Controls induced draft and indoor blower motor; humidifier output, spark ignitor and gas valve
  • Monitors timing, trial for ignition, flame sensing and lockout
  • 100% lockout safety feature
  • Compatible with LP or natural gas
  • Status LEDs for fault codes to aid in troubleshooting

SPECIFICATIONS:

 Control Voltage: 24 VAC (18-30 VAC), 60 Hz
 Line Voltage: 115 VAC, 60 Hz
 Power cons: 0.3A plus gas valve current at 24 VAC
 Operating temp: -40°F to 176°F (-40°C to 75°C)

 

Timing:

 Pre-purge: 30 seconds
 Trial for ignition: 7 seconds
 Retries: Two groups of two, 30 seconds delay within the group and 3 minutes delay between groups
 Lockout: 1 hour
 Post-purge: 90, 120, 160 and 180 seconds

Replaces:

Rheem: 62-24140-04