- Microprocessor-based precision
- Controls inducer and blower fan motors, hot surface ignitor, & gas valve
- Monitors timing, trial for ignition, flame sensing, pressure and limit switches, and lockout
- Designed for 100% gas shutoff in case of ignition failure
- Reverse polarity protection
- Twinning compatible with another ICM286 control board
- Compatible with LP or natural gas
- Diagnostic LED to aid in testing/troubleshooting
- Trial for Ignition: 7 seconds
- Pre-purge Time: 15 seconds
- Ignitor Warm Up Time: 7 seconds
- Post-Purge Time: 15 seconds
- Total Trials for Ignition: 3 (auto reset after 1 hour)
- Heat Blower On: 30 seconds
- Heat Blower Off: Selectable 90/120/150/180 seconds
- Fan (Heat) On/Off Delay: 1 sec.
- Cool On: 5 seconds
- Cool Off: 45 seconds
- REPLACES
-
Goodman 0130F00005S Grainger 29TH96 White-Rodgers 50A55-743 Goodman B18099-26S Goodman PCBBF112S