904081 Nordyne 24 VAC ½″ Natural Gas Valve with LP Conversion Kit
904081 Nordyne 24 VAC ½″ Natural Gas Valve with LP Conversion Kit
Product Overview
904081 is a genuine OEM Nordyne 24 VAC gas valve assembly with a ½″ port for natural gas and includes a propane (LP) conversion kit. Priced at $121.81 each, it ships with the factory LP conversion spring and hardware. Availability: 134 units in stock.
Cross-Reference Part Numbers
| OEM Part Number | Manufacturer | Notes |
|---|---|---|
| 904081 | Nordyne | OEM 24 VAC ½″ natural gas valve with LP conversion kit |
| 36E44 | White-Rodgers | Equivalent universal 24 VAC ½″ valve kit, includes LP conversion |
| 720-553 | Robertshaw | Universal 24 VAC valve kit with LP/Nat conversion springs |
| V4055B1014 | Honeywell | Universal 24 VAC ½″ valve kit, LP kit included |
Always verify cross-reference numbers with the original equipment manufacturer’s data plate or service manual.
Compatibility
This valve assembly directly replaces OEM valves on Nordyne, Miller-Nordyne, Coleman-Evcon, Ducane, and select private-label furnaces originally equipped with ½″ 24 VAC gas valves. Typical series and models include:
-
Nordyne G3, G4, G5, G6 and L1RA furnaces
-
Miller-Nordyne Classic® and Platinum™ series
-
Coleman-Evcon II and Performance™ series
-
Ducane state-of-the-art gas furnace lines
Always confirm compatibility by matching the furnace model number and consulting the unit’s data plate.
Technician Notes
-
De-energize all line-voltage and 24 VAC control power and shut off the gas supply before servicing.
-
Tag or photograph existing gas valve connections and manifold tubing to ensure accurate reassembly.
-
Mount the replacement valve on the manifold flange; torque mounting screws per OEM specs.
-
Verify 24 VAC at the valve coil terminals (R to C) before installation.
-
For LP service, remove the natural gas spring and install the factory LP spring and orifice furnished in the kit.
-
Adjust manifold pressure with a manometer: 3.5″ WC for natural gas, 10″ WC for propane.
-
Perform a leak test on all tubing joints and manifold connections at 10″ WC air pressure.
-
Energize the system and initiate a heat call; confirm proper valve opening, stable flame, and correct manifold pressure.