Time delay relay board Nordyne 622181R

622181R Nordyne time delay relay board

  • $ 33.33
    Unit price per 
  • Save $ 9.38
Shipping calculated at checkout.


622181R Nordyne time delay relay board

Description

622181R is a direct-replacement time delay relay board for Nordyne HVAC equipment. It provides a 40-second off-delay to keep the blower running briefly after the thermostat call ends, helping to clear residual heat and improve system efficiency. The PCB measures 4.5″ × 2″, features pre-drilled mounting holes, and uses standard spade-type terminals for quick, fool-proof installation.


Compatibility

  • OEM cross-references

    • 1005-177A

    • 1005-83-171

  • Designed for Nordyne (and equivalent Intertherm/Westinghouse) furnaces, air handlers, and packaged units that utilize a time delay relay board.

  • Commonly found on single-speed blower motors in residential heating and cooling systems.

  • To verify fit, compare your existing board’s dimensions, mounting hole spacing, and terminal layout with the specifications above.


Technical Specifications

Parameter Specification
Off-Delay Time 40 seconds
PCB Size (L × W) 4.5″ × 2″
Mounting Pre-drilled holes
Terminals Standard spade tabs
Power Source AC-powered

Nordyne time delay relay board with 40 seconds off. Board measures 4.5" x 2". Also known as part # 1005-177A, 1005-83-1711A & 622181.