632622R Nordyne −1.20″ WC SPST Pressure Switch
632622R Nordyne −1.20″ WC SPST Pressure Switch
Product Overview
632622R is a genuine OEM Nordyne/Miller pressure switch calibrated to close at −1.20″ water column (WC). It proves inducer draft or differential pressure in M7-series gas furnaces and compatible packaged HVAC equipment, ensuring the control board only allows ignition when proper airflow is established.
Technical Specifications
| Specification | Detail |
|---|---|
| Switch type | SPST (Single-Pole Single-Throw) |
| Setpoint | −1.20″ WC |
| Contact action | Normally open; closes at setpoint |
| Contact rating | 1 A @ 120 VAC resistive (verify on data plate) |
| Pressure connection | 1/4″ OD vacuum hose barb |
| Electrical terminals | Two 1/4″ male spade quick-connect |
| Operating temperature | –40 °F to 175 °F |
| Housing | Epoxy-filled die-cast aluminum |
| Weight | 0.11 lb |
Cross-Reference Part Numbers
| OEM Part Number | Notes |
|---|---|
| 632622R | Current revision |
| 632622 | Original non-revision “R” |
Compatibility
Fits Nordyne, Miller, Frigidaire, Maytag, White-Westinghouse, Tappan, Intertherm, Gibson, Kelvinator, GrandAire, Philco, Garrison, Mammoth, Medallion and other private-label furnaces requiring a −1.20″ WC SPST pressure switch for inducer draft or flame rollout proving. Always verify the required setpoint and mounting style against the unit’s data plate or service manual before ordering.
Technician Notes
-
De-energize all power and shut off the gas supply before servicing.
-
Depressurize the inducer housing; confirm zero vacuum at the switch tubing.
-
Photograph or label existing vacuum tubing routing and terminal connections.
-
Remove the old switch from its mounting boss; inspect barb and tubing for debris.
-
Hand-thread the new 632622R onto the plenum boss; torque to OEM specification.
-
Push 1/4″ vacuum tubing fully onto the barb; secure with a spring clamp if applicable.
-
Reconnect control wiring to the spade terminals, ensuring snug, corrosion-free contact.
-
Restore power and call for heat; confirm the inducer runs and the switch closes at approximately −1.20″ WC (verify with a manometer).
-
If the furnace locks out, re-check setpoint with manometer, tubing integrity, and contact continuity.