632492R Nordyne PRESSURE SWITCH -0.50"WC SPST

632492R Nordyne PRESSURE SWITCH -0.50"WC SPST

  • $ 31.45
    Unit price per 
  • Save $ 14.22
Shipping calculated at checkout.


632492R Nordyne PRESSURE SWITCH -0.50"WC SPST

Product Overview

The 632492R Nordyne pressure switch monitors inducer draft in residential gas furnaces and air handlers, ensuring safe system performance by verifying that the inducer motor creates sufficient vacuum before ignition. Factory-set to actuate at –0.50" water column, this direct-fit OEM replacement delivers consistent operation and accurate response to protect burners from unvented combustion conditions.


Technical Specifications

Parameter Specification
Setpoint (trip pressure) –0.50" W.C. (nominal)
Switch type Differential vacuum
Contact configuration SPST; normally open until vacuum reached then closed
Proof pressure 2.5" W.C. (maximum)
Burst pressure 5.0" W.C. (maximum)
Electrical rating 3 A @ 120 VAC (resistive)
Inlet fitting 1/8" hose barb
Terminals ¼" quick-connect spade
Housing material High-temperature thermoplastic
Operating temperature range –40 °F to 180 °F (–40 °C to 82 °C)
Dimensions (L × W × H) 2.0" × 1.2" × 1.3" (approx.)
Weight 0.10 lb (45 g)


Cross-Reference Part Numbers

  • Nordyne 632492R

  • Nordyne 632492

  • Coleman 632492R

  • Robertshaw PS205

  • White-Rodgers 36D47

  • Foster A501A


Compatibility

The 632492R pressure switch fits a wide range of inducer-equipped gas furnaces and air handlers across major OEMs:

  • Nordyne and Coleman N5, N6, P5, P6 series

  • York and Westinghouse standard-efficiency units

  • Goodman and Amana GSX/GMV series

  • Bryant, Payne, and Rheem single-stage models

  • American Standard Basic Heat and Pro-Line lines


Technician Notes

  • Always disconnect power and verify zero voltage before servicing.

  • Use clean, flexible 1/8" tubing; avoid kinks and secure with proper clamps.

  • Mount the switch in the original orientation and location to maintain calibration.

  • Test actuation with a calibrated manometer or vacuum pump: continuity should close at –0.50" W.C. under suction and open at ambient.

  • Inspect tubing and fittings for wear or leaks; replace as needed to ensure accurate performance.

  • Carry spare 632492R switches, tubing, and clamps on service calls for rapid field replacement.

  • Consider bundling with inducer gaskets and control fuses to create a comprehensive safety-kit offering.