632489R 0.70" WC SPST Pressure Switch 0.70" WC SPST Pressure Switch
632489R 0.70" WC SPST Pressure Switch
Product Overview
632489R is an OEM 0.70 in WC single-pole single-throw (SPST) pressure switch designed to sense inducer draft or differential pressure in gas furnaces and packaged HVAC units. It provides reliable, fast-action switching at a fixed 0.70 in WC setpoint, ensuring the control board receives a positive pressure signal before allowing ignition or maintaining burner operation.
Technical Specifications
-
Setpoint: 0.70 in WC (water column)
-
Contact arrangement: SPST, normally open until pressure reaches setpoint
-
Contact rating: 1 A @ 120 VAC (confirm on appliance data plate)
-
Pressure connection: 1/4 in OD hose barb
-
Terminals: dual 1/4 in male spade quick-connect
-
Housing: epoxy-filled die-cast aluminum
-
Ambient temperature range: –40 °F to 175 °F
-
Shipping weight: 0.11 lb
-
Packaged dimensions: 10 × 12 × 12 in, 10 oz
| Location | On-hand | Committed | Available |
|---|---|---|---|
| warehouse | 0 | 0 | 154 |
Cross-Reference Part Numbers
| OEM Part Number | Notes |
|---|---|
| 632489R | Factory-authorized pressure switch |
| 632489 | Original part without revision “R” |
Compatibility
Fits a wide range of Nordyne, Coleman, Concord, Nortek and private-label gas furnaces and packaged units that require a 0.70 in WC SPST pressure switch for inducer draft proving or flame rollout protection. Common applications include:
-
M1 series gas furnaces
-
Single-stage and multi-stage burner assemblies
-
Packaged rooftop units with induced-draft blowers
Always verify your unit’s required setpoint and mounting style against the appliance data plate before ordering.
Technician Notes
-
De-energize the furnace and shut off the gas supply.
-
Depressurize the inducer housing—verify zero pressure at the switch tubing.
-
Photograph or label the old switch’s tubing and wiring connections.
-
Remove the old switch from its mounting boss and inspect the hose barb for debris.
-
Hand-thread the new 632489R switch onto the boss; torque to OEM specification.
-
Connect 1/4 in tubing and push fully onto the barb; secure with a spring clamp if used.
-
Reattach control wiring to spade terminals, ensuring tight fit.
-
Restore power and call for heat; confirm inducer runs and the switch closes at ~0.70 in WC.
-
If the blower starts but the furnace locks out, verify setpoint with a manometer and check for tubing leaks.