626618 Neuco L175-40 High-Limit Control

626618 Neuco L175-40 High-Limit Control

  • $ 14.71
    Unit price per 
  • Save $ 5.20
Shipping calculated at checkout.


626618 Nordyne L175-40 High-Limit Control

Product Overview

Genuine Nordyne OEM high-limit control designed for residential gas furnace safety applications. The L175-40 opens at 175 °F to shut down burner operation and automatically resets once it cools by 40 °F. Compact and reliable, it protects heat exchangers from overheating and ensures safe cycling.


Technical Specifications

Specification Detail
Cut-out temperature 175 °F
Differential reset 40 °F
Switch type SPST normally closed, automatic reset
Terminals Two 1/4″ male quick-connect spades
Lead length 6 in (each)
Mounting style Snap-in bracket
Net weight 0.03 lb
Shipping dimensions 10 × 12 × 12 in
Shipping weight 10 oz


Cross-Reference Part Numbers

Our SKU Equivalent Part Function
626618 L175-40 High-limit safety temperature switch


Compatibility

Fits most Nordyne, Coleman, Heil, Westinghouse, and private-label gas furnaces originally equipped with an L175-40 high-limit control. Before ordering, verify:

  • Cut-out/reset temperatures match furnace data plate

  • Mounting bracket style and snap-in dimensions

  • Terminal and lead-wire length requirements


Installation & Technician Notes

  • Disconnect all power and gas supplies; follow lockout/tagout procedures.

  • Remove access panels to expose the burner compartment and limit control location.

  • Photograph or tag existing wiring to ensure correct re-connection.

  • Depress the snap-in bracket to release the old limit control; disconnect the spade terminals.

  • Snap the new 626618 control into place, confirm bracket engagement, and reconnect each spade to its original terminal.

  • Restore power and initiate a heat call; verify the burner cycles off at the correct temperature and that the control resets automatically as the system cools.

  • Inspect all connections and wiring for tightness and proper insulation.