S1-2702-4091 Coleman York Motor Isolator Kit
S1-2702-4091 Coleman York Motor Isolator Kit
Upgrade your blower motor’s longevity and performance with the genuine Coleman S1-2702-4091 motor isolator kit. This easy-install kit includes three precision-molded rubber grommets that fit a ¾″ mounting hole, dampening vibration and noise for quieter, smoother operation. Ideal for replacing worn or cracked mounts, it ensures motors stay securely in place while protecting housing and ductwork from motor-induced rattles.
Cross Reference
| Kit P/N | Replaces P/N |
|---|---|
| S1-2702-4091 | 7670-3551; 026-34736-000; 026-34037-000; 7660-3541 |
| Works With | 7670-5391; 8680-5391 |
Technician Notes
-
Inspect mounting holes for burrs or debris; ensure a clean ¾″ aperture before installing grommets.
-
Lubricate gromet ID with a light coating of silicone grease for easier installation and long-term resilience.
-
Push each grommet fully into the mounting flange until the lip seats flush; verify all three sit evenly.
-
Slide motor clamp (e.g., 7670-5391 or 8680-5391) through grommets and torque clamp bolt to manufacturer’s spec (approx. 60 in-lb).
-
After installation, run the motor at all speeds to confirm vibration isolation and check for any metal-to-metal contact.
Compatibility
| Application | Models / Series |
|---|---|
| Coleman Gas Furnaces | 7600, 7624, 7654, 7680 series |
| York & Miller Furnaces | DGAS, DGAT, DLAS, DM7 series |
| Aftermarket C-Frame Motors | All 48-frame, ¾″ hole motor mounts |
| Mobile Home & RV Units | Ventline / Dometic C-frame blower assemblies |
| Light Commercial Blowers | Broan-NuTone inline ventilators |
Coleman motor isolator kit includes everything seen in photo. Three rubber gromets fit in a 3/4" hole. Used with motor mounts 7670-5391, 8680-5391 & possibly others.
Replaces 7670-3551, 026-34736-000, 026-34037-000 & 7660-3541.